Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 202
Filtrar
1.
Emerg Med J ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658053

RESUMO

OBJECTIVES: Only a small proportion of patients presenting to an ED with headache have a serious cause. The SNNOOP10 criteria, which incorporates red and orange flags for serious causes, has been proposed but not well studied. This project aims to compare the proportion of patients with 10 commonly accepted red flag criteria (singly and in combination) between patients with and without a diagnosis of serious secondary headache in a large, multinational cohort of ED patients presenting with headache. METHODS: Secondary analysis of data obtained in the HEAD and HEAD-Colombia studies. The outcome of interest was serious secondary headache. The predictive performance of 10 red flag criteria from the SNNOOP10 criteria list was estimated individually and in combination. RESULTS: 5293 patients were included, of whom 6.1% (95% CI 5.5% to 6.8%) had a defined serious cause identified. New neurological deficit, history of neoplasm, older age (>50 years) and recent head trauma (2-7 days prior) were independent predictors of a serious secondary headache diagnosis. After adjusting for other predictors, sudden onset, onset during exertion, pregnancy and immune suppression were not associated with a serious headache diagnosis. The combined sensitivity of the red flag criteria overall was 96.5% (95% CI 93.2% to 98.3%) but specificity was low, 5.1% (95% CI 4.3% to 6.0%). Positive predictive value was 9.3% (95% CI 8.2% to 10.5%) with negative predictive value of 93.5% (95% CI 87.6% to 96.8%). CONCLUSION: The sensitivity and specificity of the red flag criteria in this study were lower than previously reported. Regarding clinical practice, this suggests that red flag criteria may be useful to identify patients at higher risk of a serious secondary headache cause, but their low specificity could result in increased rates of CT scanning. TRIAL REGISTRATION NUMBER: ANZCTR376695.

3.
J Adv Nurs ; 2024 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-38186205

RESUMO

AIM: To explore the views of neonatal intensive care nursing staff on the deliverability of a novel genetic point-of-care test detecting a genetic variant associated with antibiotic-induced ototoxicity. DESIGN: An interpretive, descriptive, qualitative interview study. METHODS: Data were collected using semi-structured interviews undertaken between January and November 2020. Participants were neonatal intensive care nursing staff taking part in the Pharmacogenetics to Avoid Loss of Hearing trial. RESULTS: Thematic analysis resulted in four themes: perceived clinical utility; the golden hour; point-of-care device; training and support. Recommendations were made to streamline the protocol and ongoing training and support were considered key to incorporating the test into routine care. CONCLUSION: Exploring the views of nurses involved in the delivery of the point-of-care test was essential in its implementation. By the study endpoint, all participants could see the value of routine clinical introduction of the point-of care test. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: Nurses are in a key position to support the delivery of point-of-care genetic testing into mainstream settings. This study has implications for the successful integration of other genetic point-of-care tests in acute healthcare settings. IMPACT: The study will help to tailor the training and support required for routine deployment of the genetic point-of-care test. The study has relevance for nurses involved in the development and delivery of genetic point-of-care tests in other acute hospital settings. REPORTING METHOD: This qualitative study adheres to the Standards for Reporting Qualitative Research EQUATOR guidelines and utilizes COREQ and SRQR checklists. PATIENT OR PUBLIC CONTRIBUTION: All staff working on the participating neonatal intensive care units were trained to use the genetic point-of-care test. All inpatients on the participating units were eligible to have testing via the point-of-care test. The Pharmacogenetics to Avoid Loss of Hearing Patient and Public Involvement and Engagement group provided valuable feedback. TRIAL AND PROTOCOL REGISTRATION: Registered within the University of Manchester. Ethics approval reference numbers: IRAS: 253102 REC reference: 19/NW/0400. Also registered with the ISRCTN ref: ISRCTN13704894.

4.
Childs Nerv Syst ; 40(3): 813-821, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37851125

RESUMO

PURPOSE: The consistency and accuracy of paediatric TBI triage tools can be affected by different factors, such as patients' characteristics and the level of knowledge and skill of the caregiver. This systematic review included all the available data on the level of agreement between paramedics and ED physicians about the reliability of tools to identify paediatric TBI and the diagnostic accuracy of several such tools in prehospital settings when used by paramedics. METHODS: MEDLINE (OVID), EMBASE (OVID), Cochrane Library (OVID), and CINAHL Plus (EBSCO) databases were searched from inception to 27 October 2022. Quality, bias, and applicability were assessed using COSMIN for interobserver reliability studies and QUADAS-2 tool for diagnostic accuracy studies. Narrative synthesis was employed because data were unsuitable for meta-analysis. RESULTS: Initial searches identified 660 papers in total. Five met the inclusion criteria. Two studies showed moderate agreement between paramedics and ED physicians for GCS assessment. The PTS overtriage rate was 10% and the undertriage rate was 62%, while the triage tape had an overtriage rate of 18% and an undertriage rate of 68%. Pre-hospital GCS had 86.67% sensitivity and 71.43% specificity [95% CI]: 0.74-0.96 for neurosurgically significant TBI. CONCLUSION: Low level of GCS agreement and poor diagnostic accuracy may cause further harm to the patient; thus, further studies are recommended to improve the prehospital management of children with head injuries.


Assuntos
Lesões Encefálicas Traumáticas , Traumatismos Craniocerebrais , Médicos , Humanos , Criança , Triagem , Reprodutibilidade dos Testes , Lesões Encefálicas Traumáticas/diagnóstico
5.
Pediatr Emerg Care ; 40(1): 16-21, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37195679

RESUMO

OBJECTIVE: Unplanned reattendances to the pediatric emergency department (PED) occur commonly in clinical practice. Multiple factors influence the decision to return to care, and understanding risk factors may allow for better design of clinical services. We developed a clinical prediction model to predict return to the PED within 72 hours from the index visit. METHODS: We retrospectively reviewed all attendances to the PED of Royal Manchester Children's Hospital between 2009 and 2019. Attendances were excluded if they were admitted to hospital, aged older than 16 years or died in the PED. Variables were collected from Electronic Health Records reflecting triage codes. Data were split temporally into a training (80%) set for model development and a test (20%) set for internal validation. We developed the prediction model using LASSO penalized logistic regression. RESULTS: A total of 308,573 attendances were included in the study. There were 14,276 (4.63%) returns within 72 hours of index visit. The final model had an area under the receiver operating characteristic curve of 0.64 (95% confidence interval, 0.63-0.65) on temporal validation. The calibration of the model was good, although with some evidence of miscalibration at the high extremes of the risk distribution. After-visit diagnoses codes reflecting a nonspecific problem ("unwell child") were more common in children who went on to reattend. CONCLUSIONS: We developed and internally validated a clinical prediction model for unplanned reattendance to the PED using routinely collected clinical data, including markers of socioeconomic deprivation. This model allows for easy identification of children at the greatest risk of return to PED.


Assuntos
Serviço Hospitalar de Emergência , Modelos Estatísticos , Criança , Humanos , Idoso , Estudos Retrospectivos , Prognóstico , Hospitais Pediátricos
6.
Front Immunol ; 14: 1276171, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38077362

RESUMO

Background and objectives: There is a need to develop objective risk stratification tools to define efficient care pathways for trauma patients. Biomarker-based point of care testing may strengthen existing clinical tools currently available for this purpose. The dysregulation of pro- and anti-inflammatory cytokines in the pathogenesis of organ failure is well recognised. This study was carried out to evaluate whether blood concentrations of IL-6, IL-10, and IL-6:IL-10 ratios in the early stages of the illness are significantly different in patients with worsening organ function. Materials and methods: In this prospective observational cohort study, plasma concentrations of IL-6 and IL-10 on days 1, 3 and 5 were measured in 91 major trauma patients using a multiplexed cytometric bead array approach. A composite measure of adverse outcome - defined as SOFA ≥ 2 or mortality at 7 days, was the primary outcome. IL-6 and IL-10 concentrations in early samples (days 1, 3 & 5) in patients who developed SOFA ≥ 2 on day 7 were compared against those who did not. Similar composite outcome groups at day 5 and in groups with worsening or improving SOFA scores (ΔSOFA) at days 7 and 5 were undertaken as secondary analyses. Results: Stratification on day 7, 44 (48%) patients showed adverse outcomes. These adverse outcomes associated with significantly greater IL-6 concentrations on days 1 and 5 (Day 1: 47.65 [23.24-78.68] Vs 73.69 [39.93 - 118.07] pg/mL, P = 0.040 and Day 5: 12.85 [5.80-19.51] Vs 28.90 [8.78-74.08] pg/mL; P = 0.0019). Similarly, IL-10 levels were significantly greater in the adverse outcome group on days 3 and 5 (Day 3: 2.54 [1.76-3.19] Vs 3.16 [2.68-4.21] pg/mL; P = 0.044 and Day 5: 2.03 [1.65-2.55] Vs 2.90 [2.00-5.06] pg/mL; P <0.001). IL-6 and IL-10 concentrations were also significantly elevated in the adverse outcome groups at day 3 and day 5 when stratified on day 5 outcomes. Both IL-6 and IL-6:IL-10 were found to be significantly elevated on days 1 and 3 when stratified based on ΔSOFA at day 5. This significance was lost when stratified on day 7 scores. Conclusions: Early IL-6 and IL-10 concentrations are significantly greater in patients who develop worsening organ functions downstream. These differences may provide an alternate biomarker-based approach to strengthen risk stratification in trauma patients.


Assuntos
Interleucina-10 , Interleucina-6 , Humanos , Biomarcadores , Interleucinas , Prognóstico , Estudos Prospectivos
8.
PLoS One ; 18(7): e0288612, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37478103

RESUMO

BACKGROUND AND OBJECTIVE: Point-of-care lateral flow device antigen testing has been used extensively to identify individuals with active SARS-CoV-2 infection in the community. This study aimed to evaluate the diagnostic accuracy of two point-of-care tests (POCTs) for SARS-CoV-2 in routine community care. METHODS: Adults and children with symptoms consistent with suspected current COVID-19 infection were prospectively recruited from 19 UK general practices and two COVID-19 testing centres between October 2020 and October 2021. Participants were tested by trained healthcare workers using at least one of two index POCTs (Roche-branded SD Biosensor Standard™ Q SARS-CoV-2 Rapid Antigen Test and/or BD Veritor™ System for Rapid Detection of SARS-CoV-2). The reference standard was laboratory triplex reverse transcription quantitative PCR (RT-PCR) using a combined nasal/oropharyngeal swab. Diagnostic accuracy parameters were estimated, with 95% confidence intervals (CIs), overall, in relation to RT-PCR cycle threshold and in pre-specified subgroups. RESULTS: Of 663 participants included in the primary analysis, 39.2% (260/663, 95% CI 35.5% to 43.0%) had a positive RT-PCR result. The SD Biosensor POCT had sensitivity 84.0% (178/212, 78.3% to 88.6%) and specificity 98.5% (328/333, 96.5% to 99.5%), and the BD Veritor POCT had sensitivity 76.5% (127/166, 69.3% to 82.7%) and specificity 98.8% (249/252, 96.6% to 99.8%) compared with RT-PCR. Sensitivity of both devices dropped substantially at cycle thresholds ≥30 and in participants more than 7 days after onset of symptoms. CONCLUSIONS: Both POCTs assessed exceed the Medicines and Healthcare products Regulatory Agency target product profile's minimum acceptable specificity of 95%. Confidence intervals for both tests include the minimum acceptable sensitivity of 80%. In symptomatic patients, negative results on these two POCTs do not preclude the possibility of infection. Tests should not be expected to reliably detect disease more than a week after symptom onset, when viral load may be reduced. REGISTRATION: ISRCTN142269.


Assuntos
COVID-19 , Adulto , Criança , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , Testes Imediatos , Atenção Primária à Saúde , SARS-CoV-2 , Sensibilidade e Especificidade , Reino Unido
9.
Ann Emerg Med ; 82(4): 439-448, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37306636

RESUMO

STUDY OBJECTIVE: Chest pain is one of the most common reasons for emergency ambulance calls. Patients are routinely transported to the hospital to prevent acute myocardial infarction (AMI). We evaluated the diagnostic accuracy of clinical pathways in the out-of-hospital environment. The Troponin-only Manchester Acute Coronary Syndromes decision aid and History, ECG, Age, Risk Factors, Troponin score require cardiac troponin (cTn) measurement, whereas the History and ECG-only Manchester Acute Coronary Syndromes decision aid and History, ECG, Age, Risk Factors score do not. METHODS: We conducted a prospective diagnostic accuracy study at 4 ambulance services and 12 emergency departments between February 2019 and March 2020. We included patients who received an emergency ambulance response in whom paramedics suspected AMI. Paramedics recorded the data required to calculate each decision aid and took venous blood samples in the out-of-hospital environment. Samples were tested using a point-of-care cTn assay (Roche cobas h232) within 4 hours. The target condition was a diagnosis of type 1 AMI, adjudicated by 2 investigators. RESULTS: Of 817 included participants, 104 (12.8%) had AMI. Setting the cutoff at the lowest risk group, Troponin-only Manchester Acute Coronary Syndromes had 98.3% sensitivity (95% confidence interval 91.1% to 100%) and 25.5% specificity (21.4% to 29.8%) for type 1 AMI. History, ECG, Age, Risk Factors, Troponin had 86.4% sensitivity (75.0% to 98.4%) and 42.2% specificity (37.5% to 47.0%); History and ECG-only Manchester Acute Coronary Syndromes had 100% sensitivity (96.4% to 100%) and 3.1% specificity (1.9% to 4.7%), whereas History, ECG, Age, Risk Factors had 95.1% sensitivity (88.9% to 98.4%) and 12.1% specificity (9.8% to 14.8%). CONCLUSION: With point-of-care cTn testing, decision aids can identify patients at a low risk of type 1 AMI in the out-of-hospital environment. When used alongside clinical judgment, and with appropriate training, such tools may usefully enhance out-of-hospital risk stratification.


Assuntos
Síndrome Coronariana Aguda , Infarto do Miocárdio , Humanos , Síndrome Coronariana Aguda/diagnóstico , Procedimentos Clínicos , Estudos Prospectivos , Infarto do Miocárdio/diagnóstico , Troponina , Hospitais
10.
Eur J Emerg Med ; 30(5): 356-364, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37310953

RESUMO

BACKGROUND AND IMPORTANCE: Recommended indications for emergency computed tomography (CT) brain scans are not only complex and evolving, but it is also unknown whether they are being followed in emergency departments (EDs). OBJECTIVE: To determine the CT utilization and diagnostic yield in the ED in patients with headaches across broad geographical regions. DESIGN: Secondary analysis of data from a multinational cross-sectional study of ED headache presentations over one month in 2019. SETTING AND PARTICIPANTS: Hospitals from 10 participating countries were divided into five geographical regions [Australia and New Zealand (ANZ); Colombia; Europe: Belgium, France, UK, and Romania; Hong Kong and Singapore (HKS); and Turkey). Adult patients with nontraumatic headache as the primary presenting complaint were included. Patients were identified from ED management systems. OUTCOME MEASURES AND ANALYSIS: The outcome measures were CT utilization and diagnostic yield. CT utilization was calculated using a multilevel binary logistic regression model to account for clustering of patients within hospitals and regions. Imaging data (CT requests and reports) were sourced from radiology management systems. MAIN RESULTS: The study included 5281 participants. Median (interquartile range) age was 40 (29-55) years, 66% were women. Overall mean CT utilization was 38.5% [95% confidence interval (CI), 30.4-47.4%]. Regional utilization was highest in Europe (46.0%) and lowest in Turkey (28.9%), with HKS (38.0%), ANZ (40.0%), and Colombia (40.8%) in between. Its distribution across hospitals was approximately symmetrical. There was greater variation in CT utilization between hospitals within a region than between regions (hospital variance 0.422, region variance 0.100). Overall mean CT diagnostic yield was 9.9% (95% CI, 8.7-11.3%). Its distribution across hospitals was positively skewed. Regional yield was lower in Europe (5.4%) than in other regions: Colombia (9.1%), HKS (9.7%), Turkey (10.6%), and ANZ (11.2%). There was a weak negative correlation between utilization and diagnostic yield ( r  = -0.248). CONCLUSION: In this international study, there was a high variation (28.9-46.6%) in CT utilization and diagnostic yield (5.4-11.2%) across broad geographic regions. Europe had the highest utilization and the lowest yield. The study findings provide a foundation to address variation in neuroimaging in ED headache presentations.


Assuntos
Cefaleia , Tomografia Computadorizada por Raios X , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Transversais , Cefaleia/diagnóstico por imagem , Serviço Hospitalar de Emergência , Neuroimagem , Encéfalo
11.
J Am Coll Cardiol ; 82(1): 60-69, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37380305

RESUMO

The term "single-sample rule-out" refers to the ability of very low concentrations of high-sensitivity cardiac troponin (hs-cTn) on presentation to exclude acute myocardial infarction with high clinical sensitivity and negative predictive value. Observational and randomized studies have confirmed this ability. Some guidelines endorse use of a concentration of hs-cTn at the assay's limit of detection, while other studies have validated the use of higher concentrations, allowing this approach to identify a greater proportion of patients at low risk. In most studies, at least 30% of patients can be triaged with this approach. The concentration of hs-cTn varies according to the assay used and sometimes how regulations permit reporting. It is clear that patients need to be at least 2 hours from the onset of symptoms being evaluated. Caution is warranted, particularly with older patients, women, and patients with underlying cardiac comorbidities.


Assuntos
Infarto do Miocárdio , Humanos , Feminino , Infarto do Miocárdio/diagnóstico , Coração , Triagem , Troponina
12.
Eur Heart J Acute Cardiovasc Care ; 12(9): 633-643, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37163667

RESUMO

Emergency department (ED) crowding is a worsening global problem caused by hospital capacity and other health system challenges. While patients across a broad spectrum of illnesses may be affected by crowding in the ED, patients with cardiovascular emergencies-such as acute coronary syndrome, malignant arrhythmias, pulmonary embolism, acute aortic syndrome, and cardiac tamponade-are particularly vulnerable. Because of crowding, patients with dangerous and time-sensitive conditions may either avoid the ED due to anticipation of extended waits, leave before their treatment is completed, or experience delays in receiving care. In this educational paper, we present the underlying causes of crowding and its impact on common cardiovascular emergencies using the input-throughput-output process framework for patient flow. In addition, we review current solutions and potential innovations to mitigate the negative effect of ED crowding on patient outcomes.


Assuntos
Emergências , Serviço Hospitalar de Emergência , Humanos , Aglomeração
13.
Microbiol Spectr ; 11(3): e0504422, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37212699

RESUMO

The COVID-19 pandemic has given rise to numerous commercially available antigen rapid diagnostic tests (Ag-RDTs). To generate and to share accurate and independent data with the global community requires multisite prospective diagnostic evaluations of Ag-RDTs. This report describes the clinical evaluation of the OnSite COVID-19 rapid test (CTK Biotech, CA, USA) in Brazil and the United Kingdom. A total of 496 paired nasopharyngeal (NP) swabs were collected from symptomatic health care workers at Hospital das Clínicas in São Paulo, Brazil, and 211 NP swabs were collected from symptomatic participants at a COVID-19 drive-through testing site in Liverpool, United Kingdom. Swabs were analyzed by Ag-RDT, and results were compared to quantitative reverse transcriptase PCR (RT-qPCR). The clinical sensitivity of the OnSite COVID-19 rapid test in Brazil was 90.3% (95% confidence interval [CI], 75.1 to 96.7%) and in the United Kingdom was 75.3% (95% CI, 64.6 to 83.6%). The clinical specificity in Brazil was 99.4% (95% CI, 98.1 to 99.8%) and in the United Kingdom was 95.5% (95% CI, 90.6 to 97.9%). Concurrently, analytical evaluation of the Ag-RDT was assessed using direct culture supernatant of SARS-CoV-2 strains from wild-type (WT), Alpha, Delta, Gamma, and Omicron lineages. This study provides comparative performance of an Ag-RDT across two different settings, geographical areas, and populations. Overall, the OnSite Ag-RDT demonstrated a lower clinical sensitivity than claimed by the manufacturer. The sensitivity and specificity from the Brazil study fulfilled the performance criteria determined by the World Health Organization, but the performance obtained from the UK study failed to do. Further evaluation of Ag-RDTs should include harmonized protocols between laboratories to facilitate comparison between settings. IMPORTANCE Evaluating rapid diagnostic tests in diverse populations is essential to improving diagnostic responses as it gives an indication of the accuracy in real-world scenarios. In the case of rapid diagnostic testing within this pandemic, lateral flow tests that meet the minimum requirements for sensitivity and specificity can play a key role in increasing testing capacity, allowing timely clinical management of those infected, and protecting health care systems. This is particularly valuable in settings where access to the test gold standard is often restricted.


Assuntos
COVID-19 , Humanos , Brasil , COVID-19/diagnóstico , Pandemias , Estudos Prospectivos , SARS-CoV-2 , Reino Unido , Biotecnologia , Teste para COVID-19
14.
Emerg Med J ; 40(6): 431-436, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37068929

RESUMO

OBJECTIVES: The Manchester Acute Coronary Syndromes ECG (MACS-ECG) prediction model calculates a score based on objective ECG measurements to give the probability of a non-ST elevation myocardial infarction (NSTEMI). The model showed good performance in the emergency department (ED), but its accuracy in the pre-hospital setting is unknown. We aimed to externally validate MACS-ECG in the pre-hospital environment. METHODS: We undertook a secondary analysis from the Pre-hospital Evaluation of Sensitive Troponin (PRESTO) study, a multi-centre prospective study to validate decision aids in the pre-hospital setting (26 February 2019 to 23 March 2020). Patients with chest pain where the treating paramedic suspected acute coronary syndrome were included. Paramedics collected demographic and historical data and interpreted ECGs contemporaneously (as 'normal' or 'abnormal'). After completing recruitment, we analysed ECGs to calculate the MACS-ECG score, using both a pre-defined threshold and a novel threshold that optimises sensitivity to differentiate AMI from non-AMI. This was compared with subjective ECG interpretation by paramedics. The diagnosis of AMI was adjudicated by two investigators based on serial troponin testing in hospital. RESULTS: Of 691 participants, 87 had type 1 AMI and 687 had complete data for paramedic ECG interpretation. The MACS-ECG model had a C-index of 0.68 (95% CI: 0.61 to 0.75). At the pre-determined cut-off, MACS-ECG had 2.3% (95% CI: 0.3% to 8.1%) sensitivity, 99.5% (95% CI: 98.6% to 99.9%) specificity, 40.0% (95% CI: 10.2% to 79.3%) positive predictive value (PPV) and 87.6% (87.3% to 88.0%) negative predictive value (NPV). At the optimal threshold for sensitivity, MACS-ECG had 50.6% sensitivity (39.6% to 61.5%), 83.1% specificity (79.9% to 86.0%), 30.1% PPV (24.7% to 36.2%) and 92.1% NPV (90.4% to 93.5%). In comparison, paramedics had a sensitivity of 71.3% (95% CI: 60.8% to 80.5%) with 53.8% (95% CI: 53.8% to 61.8%) specificity, 19.7% (17.2% to 22.45%) PPV and 93.3% (90.8% to 95.1%) NPV. CONCLUSION: Neither MACS-ECG nor paramedic ECG interpretation had a sufficiently high PPV or NPV to 'rule in' or 'rule out' NSTEMI alone.


Assuntos
Síndrome Coronariana Aguda , Infarto do Miocárdio sem Supradesnível do Segmento ST , Humanos , Síndrome Coronariana Aguda/diagnóstico , Troponina T , Estudos Prospectivos , Técnicas de Apoio para a Decisão , Troponina , Serviço Hospitalar de Emergência , Hospitais , Eletrocardiografia , Dor no Peito/diagnóstico , Sensibilidade e Especificidade
15.
BMJ Open ; 13(3): e068555, 2023 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-36882243

RESUMO

INTRODUCTION: Traumatic brain injury (TBI) is a major global health burden that results in disability and loss of health. Identifying those patients who require specialist neuroscience care can be challenging due to the low accuracy of existing prehospital trauma triage tools. Despite the widespread use of decision aids to 'rule out' TBI in hospitals, they are not widely used in the prehospital environment. We aim to provide a snapshot of current prehospital practices in the UK, and to explore facilitators and challenges that may be encountered when adopting new tools for decision support. METHODS AND ANALYSIS: A mixed-methods study will be conducted using a convergent design approach. In the first phase, we will conduct a national survey of current practice in which every participating ambulance service in the UK will receive an online questionnaire, and only one response is required. In the second phase, semistructured interviews will be conducted to explore the perceptions of ambulance service personnel regarding the implementation of new triage methods that may enhance triage decisions. The survey questions and the interview topic guide were piloted and externally reviewed. Quantitative data will be summarised using descriptive statistics; qualitative data will be analysed thematically. ETHICS AND DISSEMINATION: This study has been approved by the Health Research Authority (REC reference 22/HRA/2035). Our findings may inform the design of future care pathways and research as well as identify challenges and opportunities for future development of prehospital triage tools for patients with suspected TBI. Our findings will be published in peer-reviewed journals, relevant national and international conferences, and will be included in a PhD thesis.


Assuntos
Lesões Encefálicas Traumáticas , Triagem , Humanos , Lesões Encefálicas Traumáticas/diagnóstico , Lesões Encefálicas Traumáticas/terapia , Pacientes , Ambulâncias , Procedimentos Clínicos
16.
Sci Rep ; 13(1): 3887, 2023 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-36890186

RESUMO

The emergence of severe acute respiratory syndrome 2 (SARS-CoV-2) variants of concern (VOCs), with mutations linked to increased transmissibility, vaccine escape and virulence, has necessitated the widespread genomic surveillance of SARS-CoV-2. This has placed a strain on global sequencing capacity, especially in areas lacking the resources for large scale sequencing activities. Here we have developed three separate multiplex high-resolution melting assays to enable the identification of Alpha, Beta, Delta and Omicron VOCs. The assays were evaluated against whole genome sequencing on upper-respiratory swab samples collected during the Alpha, Delta and Omicron [BA.1] waves of the UK pandemic. The sensitivities of the eight individual primer sets were all 100%, and specificity ranged from 94.6 to 100%. The multiplex HRM assays have potential as a tool for high throughput surveillance of SARS-CoV-2 VOCs, particularly in areas with limited genomics facilities.


Assuntos
COVID-19 , Humanos , SARS-CoV-2/genética , Mutação , Bioensaio , Genômica
17.
PLoS One ; 18(3): e0281925, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36867620

RESUMO

OBJECTIVES: In order to generate independent performance data regarding accuracy of COVID-19 antigen-based rapid diagnostic tests (Ag-RDTs), prospective diagnostic evaluation studies across multiple sites are required to evaluate their performance in different clinical settings. This report describes the clinical evaluation the GENEDIA W COVID-19 Ag Device (Green Cross Medical Science Corp., Chungbuk, Korea) and the ActiveXpress+ COVID-19 Complete Testing Kit (Edinburgh Genetics Ltd, UK), in two testing sites Peru and the United Kingdom. METHODS: Nasopharyngeal swabs collected from 456 symptomatic patients at primary points of care in Lima, Peru and 610 symptomatic participants at a COVID-19 Drive-Through testing site in Liverpool, England were analyzed by Ag-RDT and compared to RT-PCR. Analytical evaluation of both Ag-RDTs was assessed using serial dilutions of direct culture supernatant of a clinical SARS-CoV-2 isolate from the B.1.1.7 lineage. RESULTS: For GENEDIA brand, the values of overall sensitivity and specificity were 60.4% [95% CI 52.4-67.9%], and 99.2% [95% CI 97.6-99.7%] respectively; and for Active Xpress+ the overall values of sensitivity and specificity were 66.2% [95% CI 54.0-76.5%], and 99.6% [95% CI 97.9-99.9%] respectively. The analytical limit of detection was determined at 5.0 x 102 pfu/ml what equals to approximately 1.0 x 104 gcn/ml for both Ag-RDTs. The UK cohort had lower median Ct values compared to that of Peru during both evaluations. When split by Ct, both Ag-RDTs had optimum sensitivities at Ct<20 (in Peru; 95% [95% CI 76.4-99.1%] and 100.0% [95% CI 74.1-100.0%] and in the UK; 59.2% [95% CI 44.2-73.0%] and 100.0% [95% CI 15.8-100.0%], for the GENDIA and the ActiveXpress+, respectively). CONCLUSIONS: Whilst the overall clinical sensitivity of the Genedia did not meet WHO minimum performance requirements for rapid immunoassays in either cohort, the ActiveXpress+ did so for the small UK cohort. This study illustrates comparative performance of Ag-RDTs across two global settings and considers the different approaches in evaluation methods.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Peru , Estudos Prospectivos , Reino Unido , Teste para COVID-19
18.
Clin Chem Lab Med ; 61(8): 1411-1419, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-36952681

RESUMO

The International Federation of Clinical Chemistry Committee on Clinical Applications of Cardiac Biomarkers (IFCC C-CB) provides educational documents to facilitate the interpretation and use of cardiac biomarkers in clinical laboratories and practice. Our aim is to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay. Measurements of cardiac troponin (cTn) have a prominent place in the clinical work-up of patients with suspected acute coronary syndrome. It is therefore important that clinical laboratories know how to recognize and assess analytical issues. Two emerging analytical issues resulting in falsely high cTn concentrations, often several fold higher than the upper reference limit (URL), are antibody-mediated assay interference due to long-lived cTn-antibody complexes, called macrotroponin, and crosslinking antibodies that are frequently referred to as heterophilic antibodies. We provide an overview of antibody-mediated cTn assay interference and provide recommendations on how to confirm the interference and interpret the results.


Assuntos
Infarto do Miocárdio , Humanos , Biomarcadores , Química Clínica , Anticorpos , Troponina
19.
Front Cardiovasc Med ; 10: 1142465, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38169956

RESUMO

Background: D-Dimer testing is a diagnostic tool for exclusion of deep vein thrombosis (DVT) and pulmonary embolism (PE). This study evaluated the diagnostic performance of the Tina-quant® D-Dimer Gen.2 assay (Roche Diagnostics International Ltd, Rotkreuz, Switzerland) in patients with low/intermediate pre-test probability of DVT/PE using standard, age-, and clinical probability-adjusted cut-offs. Methods: In this prospective, observational, multicenter study (July 2017-August 2019), plasma samples were collected from hospital emergency departments and specialist referral centers. DVT/PE was diagnosed under hospital standard procedures and imaging protocols. A standard D-dimer cut-off of 0.5 µg fibrinogen equivalent units (FEU)/ml was combined with the three-level Wells score; cut-offs adjusted for age (age × 0.01 µg FEU/ml for patients >50 years) and clinical probability (1 µg FEU/ml for low probability) were also evaluated. An assay comparison was conducted in a subset of samples using the Tina-quant D-Dimer Gen.2 assay and the previously established routine laboratory assay, STA-Liatest D-Di Plus assay (Stago Deutschland GmbH, Düsseldorf, Germany). Results: 2,897 patients were enrolled; 2,516 completed the study (DVT cohort: 1,741 PE cohort: 775). Clinical assessment plus D-dimer testing using the standard cut-off resulted in 317 (DVT) and 230 (PE) false positives, and zero (DVT) and one (PE) false negatives. Negative predictive value (NPV) was 100.0% (95% confidence interval [CI]: 99.7%-100.0%) and 99.8% (95% CI: 98.8%-100.0%) for DVT and PE, respectively. After age-adjustment, NPV was 99.9% (95% CI: 99.6%-100.0%) and 99.1% (95% CI: 97.8-99.7) for DVT and PE, respectively. False positive rates decreased (>50%) in clinical probability-adjusted analyses vs. primary analysis. In the assay comparison, the performances of the two assays were comparable. Conclusion: The Tina-quant D-Dimer Gen.2 assay and standard D-dimer cut-off level combined with the three-level Wells score accurately identified patients with a very low probability of DVT/PE.

20.
Microbiol Spectr ; 10(6): e0201222, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36448777

RESUMO

The COVID-19 pandemic has led to the commercialization of many antigen-based rapid diagnostic tests (Ag-RDTs), requiring independent evaluations. This report describes the clinical evaluation of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom. The collected samples (446 nasal swabs from Brazil and 246 nasopharyngeal samples from the UK) were analyzed by the Ag-RDT and compared to reverse transcription-quantitative PCR (RT-qPCR). Analytical evaluation of the Ag-RDT was performed using direct culture supernatants of SARS-CoV-2 strains from the wild-type (B.1), Alpha (B.1.1.7), Delta (B.1.617.2), Gamma (P.1), and Omicron (B.1.1.529) lineages. An overall sensitivity and specificity of 88.2% (95% confidence interval [CI], 81.3 to 93.3) and 100.0% (95% CI, 99.1 to 100.0), respectively, were obtained for the Brazilian and UK cohorts. The analytical limit of detection was determined as 1.0 × 103 PFU/mL (Alpha), 2.5 × 102 PFU/mL (Delta), 2.5 × 103 PFU/mL (Gamma), and 1.0 × 103 PFU/mL (Omicron), giving a viral copy equivalent of approximately 2.1 × 104 copies/mL, 9.0 × 105 copies/mL, 1.7 × 106 copies/mL, and 1.8 × 105 copies/mL for the Ag-RDT, respectively. Overall, while a higher sensitivity was claimed by the manufacturers than that found in this study, this evaluation finds that the Ag-RDT meets the WHO minimum performance requirements for sensitivity and specificity of COVID-19 Ag-RDTs. This study illustrates the comparative performance of the Hotgen Ag-RDT across two global settings and considers the different approaches in evaluation methods. IMPORTANCE Since the beginning of the SARS-CoV-2 pandemic, we have witnessed growing numbers of antigen rapid diagnostic tests (Ag-RDTs) being brought to market. In the United Kingdom, this was somewhat controlled indirectly as the government offered free tests from a small number of companies. However, as this has now ceased, individuals are responsible for their own acquisition of test kits. Similarly in Brazil, as of January 2022, pharmacies and other health care retailers are permitted to sell Ag-RDTs directly to the community. Many of these Ag-RDTs have not been externally evaluated, and results are not readily available to the public. Thus, there is now a need for a transparent evaluation of Ag-RDTs with both analytical and clinical evaluation. We present an independent review of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Brasil , COVID-19/diagnóstico , Pandemias , Reino Unido , Coloide de Ouro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA